Human Neutrophil gelatinase-associated lipocalin (NGAL) ELISA Kit (CLIA)

(No reviews yet) Write a Review
SKU:
EKU08940
Availability:
Next Week Delivery
€932
Frequently bought together:

Description

Human Neutrophil gelatinase-associated lipocalin (NGAL) ELISA Kit (CLIA) is available at Gentaur for next week delivery.

Specificity: This assay has high sensitivity and excellent specificity for detection of Neutrophil gelatinase-associated lipocalin (NGAL).

Cross Activity: This assay has high sensitivity and excellent specificity for detection of Neutrophil gelatinase-associated lipocalin (NGAL).

Test principle: The microplate provided in this kit has been pre-coated with an antibody specific to Neutrophil gelatinase-associated lipocalin (NGAL). Standards or samples are then added to the appropriate microplate wells with a biotin-conjugated antibody specific to Neutrophil gelatinase-associated lipocalin (NGAL). Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. Then the mixture of substrate A and B is added to generate glow light emission kinetics. Upon plate development, the intensity of the emitted light is proportional to the Neutrophil gelatinase-associated lipocalin (NGAL) level in the sample or standard.;

Assay procedure summary: 1. Prepare all reagents, samples and standards; 2. Add 100 µL standard or sample to each well. Incubate 2 hours at 37°C; 3. Aspirate and add 100 µL prepared Detection Reagent A. Incubate 1 hour at 37°C; 4. Aspirate and wash 3 times; 5. Add 100 µL prepared Detection Reagent B. Incubate 30 minutes at 37°C; 6. Aspirate and wash 5 times; 7. Add 100 µL Substrate Solution. Incubate 10 minutes at 37°C; 8. Read RLU value immediately.

Stability: The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition. To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Restrictions: For Research Use Only. Not for use in diagnostic procedures, drug use, or for administration to humans or animals.

Quality Systems: The kit is manufactured at ISO 9001 and ISO 13485 certified facilities.

Quality Assurance: Biomatik ELISA Kits are not typically pre-assembled as finished products due to limited shelf life. Before shipping, each kit is assembled and tested to ensure that it meets specifications before shipping. Minor changes may occur to the Detection Range, Sensitivity, and Precision. All kits are tested to confirm that they fall within their defined Inter- and Intra- assay coefficient of variation. Please always refer to the hard copy manual included in The kitbefore experiment.

Research Area: Infection immunity;

Target Synonyms: Lipocalin-2; LCN2; p25; Lipocalin 2; Oncogene 24p3; 25 kDa alpha-2-microglobulin-related subunit of MMP-9; Siderocalin LCN2

Precision: Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Neutrophil gelatinase-associated lipocalin (NGAL) were tested 20 times on one plate, respectively. Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Neutrophil gelatinase-associated lipocalin (NGAL) were tested on 3 different plates, 8 replicates in each plate. CV(%) = SD/meanX100. Intra-assay: CV<10%. Inter-Assay: CV<12%.

 

View AllClose

Additional Information

Size:
96-Well Plate
Target Name:
Neutrophil gelatinase-associated lipocalin
Species Reactivity:
Homo sapiens (Human)
Sample type:
serum, plasma, urine, tissue homogenates, cell lysates, cell culture supernates and other biological fluids
Detection range:
27.4-20,000 pg/mL
Sensitivity:
9.9 pg/mL
Detection Method:
Chemiluminescent
Assay Time:
2 hours, 40min
Application:
CLIA
Assay Type:
Double-antibody Sandwich
Shipping Condition:
Ice packs
Storage:
Short term: 4°C; Long term: see manual.
Precaution of Use:
The Stop Solution is acidic. Do not allow to contact skin or eyes.
Expiry Date:
8 months
UniProt ID:
P80188
View AllClose

0 Reviews

View AllClose